Conomel
11-18

What is the principle of an electrical fire monitoring system?

The basic principle of an electrical fire monitoring system is that when the parameters such as current and temperature in electrical equipment are abnormal or abrupt, the terminal probes (such as residual current transformers, temperature sensors, etc.) use the electromagnetic field induction principle and changes in temperature effects to this information. Collect and send it to the monitoring detector. After amplification, A / D conversion, CPU analyzes and judges the amplitude of the change, and compares it with the alarm set value. Once it exceeds the set value, it sends an alarm signal, and at the same time It is also sent to the monitoring equipment, which is further identified and judged by the monitoring equipment. When it is confirmed that a fire may occur, the monitoring host sends out a fire alarm signal, lights up the alarm indicator, sounds an alarm, and displays a fire alarm on the LCD screen. And other information. The staff on duty will quickly go to the accident site for inspection and processing based on the information displayed above, and send the alarm information to the centralized console.
11-18

Power quality issues (three-phase imbalance)

Under normal operation of the system, the unbalanced capacity and electrical location of single-phase loads (such as electrified railways, electric arc furnaces, and electric welding machines) in a three-phase system will cause the three-phase imbalance in the system.
Previous page
1

HOT INFO

Knowledge of switchgear power distribution
Knowledge of switchgear power distribution
Time of issue : 2019-11-18 16:59:00
Switchgear: refers to a complete set of power distribution devices that are assembled from primary equipment and secondary equipment according to a certain circuit scheme. It is used to control and protect the lines and equipment. It is divided into fixed and handcart styles. The line voltage level can be divided into high voltage switchgear (fixed and handcart) and low voltage switchgear (fixed and drawer). The structure of the switch cabinet is similar, and it is mainly divided into a bus room, a circuit breaker room, a secondary control room (instrument room), and a feeder room. Generally, steel plates are used to isolate the rooms.
See more information
How to solve the electrical fault?
How to solve the electrical fault?
Time of issue : 2019-11-18 16:59:00
There are various electrical fault phenomena. For example, the same type of fault may have different fault phenomena, and different types of faults may be the same fault phenomenon. The identity and diversity of this fault phenomenon bring complexity to find the fault. . However, the failure phenomenon is the basic basis for finding electrical faults and the starting point for finding electrical faults. Therefore, we must carefully observe and analyze the failure phenomena, find out the most important and typical aspects of the failure phenomena, and find out the time and place of the failure , Environment, etc.
See more information

Conomel

CONOMEL (CHINA)

Tel: 0086-755-26602705     Fax:0086-755-26909258      Mailbox:china@conomel.com

Add: No. 198, Daxin Road, Nantou Street, Nanshan District, Shenzhen

Copyright © 2019 Conomel (Shenzhen) Technology Co., Ltd. all rights reserved

粤ICP备18151755号

 

Copyright © 2019 Conomel (Shenzhen) Technology Co., Ltd. all rights reserved

粤ICP备18151755号